*This is optional for the PEI calculator*
This is the brand associated with the pump being listed. This name will appear on the label.
This is the brand associated with the pump being listed. This name will appear on the label. *This is optional for the PEI calculator*
This designation must be identical to any reported to DOE for certification of this model. Individual model numbers listed under a single basic model must have the same PEI score. This designation or the Manufacturer’s model number must appear on the pump nameplate.
Refer to 10 CFR 431 Section §431.462 (Scope & Definitions) for the definition of basic model.
This designation must be identical to any reported to DOE for certification of this model. *This is optional for the PEI calculator*
This is the unique number given to the pump being rated. A basic model can have multiple individual models listed (as separate entry) as long as they meet the same definition of basic model. This designation or the basic model number must appear on the pump nameplate. Refer to 10 CFR 429 Section 429.2 Definitions for the definition of manufacturer’s (individual) model number
This is the unique number given to the pump being rated. *This is optional for the PEI calculator*
Five pump equipment categories are within scope. Refer to 10 CFR 431 Section §431.462 (Scope & Definitions) for the definition of equipment categories.
1. End Suction Close Coupled - ESCC
2. End Suction Frame Mounted - ESFM
3. In-line - IL
4. Radially Split, multi-stage vertical in-line casing diffuser - RSV
5. Vertical turbine submersible - ST
This is the section of the uniform test procedure the model was tested too. Section III (3) is for bare pump ratings, Section IV (4) is for bare pump + motor listings where power is measured into the motor, Section V (5) is for bare pump + motor listings where motor losses are calculated, Section VI (6) is for bare pump + motor + control listings where power is measured into the control, Section VII (7) is for bare pump + motor + continuous control listings where motor and control losses are calculated. Refer to Appendix A to Subpart Y of 10 CFR 431.
This is the configuration of the individual model number as it is being rated.
This is the full impeller diameter the basic model is being listed with. Refer to 10 CFR 431 section 431.462 for the definition of full impeller diameter
This is the number of stages the basic model is being rated with for listing. ESCC, ESFM and IL pumps are only in scope with a single (1) stage. For ST and RSV pumps which may have multiple stages, all variations in number of stages of the bare pump must be considered a single basic model. Refer to Appendix A to Subpart Y of 10 CFR Part 431 – Uniform Test Method for the measurement of Energy consumption of Pumps – Section C.2 Test Conditions for Multi-sage pumps, to determine the number of stages to test and rate the basic model.
Pumps designed to operate anywhere between 1440 RPM - 2160 RPM are listed as 1800 RPM nominal and pumps designed to operated anywhere between 2880 RPM - 4320 RPM are listed as 3600 RPM nominal.
Bowl diameter is only applicable to ST pumps. ST pumps are within scope up to a 6 inch bowl diameter. Please indicate the nominal diameter of the bowls for the ST pump being listed.
This is the type of Motor.
For Section IV, V, VI and VII tests, indicate if the motor is regulated under 10 CFR 431.25
If regulated under 10 CFR 431.25, This is the nominal motor efficiency listed on the pump nameplate determined per the test procedure for 10 CFR 431.25.
Sections III, V and VII of Appendix A to Subpart Y provide methods to determine driver and control losses that are applied to a bare pump test (Calculated). For theses cases select 'Calculated'
Sections IV an VI of Appendix A to Subpart Y provide methods to determine the power consumption of the bare pump, driver and control when applicable through wire-to-water testing (Tested). For these cases select 'Tested'
For Section III tests, this the motor power used for default loss calculations.
For Section IV, V, VI and VII tests, this is the nameplate rated motor power for the basic model being listed. All individual model numbers listed under a basic model must have the same rated nameplate motor power.
Appendix A to Subpart Y of 10 CFR 431 outlines procedures to test pumps that can be tested to 120% of BEP and pumps that cannot be tested to 120% of BEP. If the pump being listed was tested to 120% of BEP, select 'Yes' and the representative load points entered will be 75%, 100% and 110% of BEP. If the pump being listed could not be tested to 120% of BEP, select 'No' and the representative load points entered will be 65%, 90% and 100% of BEP.
The "Representative" values entered must be identical to any reported to DOE for this model. The values entered for Rate of flow, Head and Driver or Control Input Power are values determined per the appropriate section of Appendix A to Subpart Y of 10 CFR 431 for a "representative sample" and "representative" values are determined per 10 CFR 429.59. Enter the 100% flow point and the other flow points will calculated.
The values entered for rate of flow, head and pump, driver or control input power at various load points are values determined per the appropriate section of Appendix A to Subpart Y of 10 CFR 431 for a "single sample"
This is the representative PEI value for the basic model as determined per 10 CFR 429.59. This value must be identical to any reported to DOE for this model.
This is the calculated PEI for a single sample. PEI reported to DOE for certification or HI in the Energy Rating Program is a representative value for the basic model determined as outlined in 10 CFR 429.59.
The representative data reported must be developed per Appendix A to Subpart Y or 10 CFR 431 and based on testing done in an HI approved laboratory (www.pumps.org/40.7). Please enter or select the HI approved laboratory that samples were tested at to develop the representative values.
*Optional for PEI calculator
Listed pumps have a status associated with them that drives whether they are visible to the public, whether they count towards your organization's subscription, and whether they can be removed from the energy ratings program entirely.
May be deleted, not visible to public, does not count towards subscription. Data corrections cannot be applied; listing should just be deleted and re-created.
Cannot be deleted, visible to all, counts towards subscription. Data corrections can be applied.
Cannot be deleted, only visible via direct link/QR, does not count towards subscription. Data corrections can be applied.
Pump status | Accessible from Rating ID / QR Code | Searchable (by Brand / Participant) | Counts towards Utility Search totals |
---|---|---|---|
Pending | No | No | No |
Active | Yes | Yes | Yes |
Inactive | Yes | No | No |
Multiple pumps may be listed (active) under the same Basic Model Designation; however they MUST all have the same ER value.Management of Basic Model and Individual Model Numbers is critical during two use cases - (1) when a pump requires data correction, and (2) when a pump has been redesigned.
This case applies to situations where the physical pump has not changed; the data is being modified due to error/omission. The listing is modified – and retains the same QR code and Rating ID.
A user can apply a data correction to any pump that is not pending.
If correction changes the ER value then:
Otherwise (the correction did not change ER value), the pump’s state remains unchanged.
Rating ID | Basic Model Designation | Individual Model Number | Energy Rating | Status |
---|---|---|---|---|
RATING_1 | BASIC_MODEL_1 | 1X1.5X8.34 | 34 | Active |
RATING_2 | BASIC_MODEL_1 | 1X1.5X8.35 | 34 | Inactive |
RATING_3 | BASIC_MODEL_2 | 1Y1.9X3.48 | 21 | Active |
RATING_4 | BASIC_MODEL_3 | 2X1.4X1.0A | 19 | Active |
RATING_5 | BASIC_MODEL_3 | 2X1.4X1.0B | 19 | Active |
RATING_6 | BASIC_MODEL_3 | 2X1.4X1.0C | 19 | Active |
This case applies when a manufacturer creates a redesign of an existing pump.
Since this is a new physical machine, it is a new listing, with a new QR code and Rating ID. The new design replaces the old design in commerce, and all pumps with the old ER value must be marked as inactive.
To do this, participant uploads the new design. The new listing cannot be activated unless all other pumps sharing the same basic model number (with different ER values) are currently inactive.
Since inactive pumps are still visible via direct link or QR code, owners of the old designs can still access the ER label for their pump. Participants can also continue to make revisions to inactive pumps.
Rating ID | Basic Model Designation | Individual Model Number | Energy Rating | Status |
---|---|---|---|---|
RATING_1 | BASIC_MODEL_1 | 1X1.5X8.34 | 34 | Active |
RATING_2 | BASIC_MODEL_1 | 1X1.5X8.35 | 34 | Inactive |
RATING_3 | BASIC_MODEL_2 | 1Y1.9X3.48 | 21 | Active |
RATING_4 | BASIC_MODEL_3 | 2X1.4X1.0A | 19 | Active |
RATING_5 | BASIC_MODEL_3 | 2X1.4X1.0B | 19 | Active |
RATING_6 | BASIC_MODEL_3 | 2X1.4X1.0C | 19 | Active |